ABUS WIRELESS ALARM SYSTEM
INSTALLATION INSTRUCTION
These installation instructions are an important product accessory. They contain important installation and operation
information. Bear this in mind if you pass the product on to others.
Store these installation instructions in a safe place for future reference.
For a list of contents with page numbers, see page 3.
For brief instructions of starting up the ABUS wireless alarm package, see page 10-86.
Zobrazit stránku 0
1 2 3 4 5 6 ... 95 96

Shrnutí obsahu

Strany 1 - INSTALLATION INSTRUCTION

ABUS WIRELESS ALARM SYSTEM INSTALLATION INSTRUCTION These installation instructions are an imp

Strany 2 - 5INWSAIMABEN-C

3-10 3.5 How can the ABUS wireless alarm system be extended? The ABUS wireless alarm system is a modular, extendable security system. The following gr

Strany 3 - Contents

3-11 3.6 CE manufacturer’s declaration EG – KONFORMITÄTSERKLÄRUNG EC – DECLARATION OF CONFIRMITY Wir / We Security-Cen

Strany 4

4-12 Chapter 4 Initial considerations Before starting to install your new ABUS wireless alarm system, please take the time to consider the following.

Strany 5

4-13 4.1 What kinds of security are there? In general, there are three different ways of securing an object: External perimeter surveillance, in whi

Strany 6 - Chapter 2 Safety information

4-14 4.3 Where do I install the ABUS wireless alarm system? The ABUS wireless alarm system should be installed in your house near an analogue telephon

Strany 7

5-15 Chapter 5 Installing the ABUS wireless alarm system Make a sketch of the object or use the architect’s plans. Enter the absolutely necessary wir

Strany 8

5-16 5.2 How do I install the ABUS wireless alarm system? The ABUS wireless alarm system is mounted on the wall in three steps. You need a flat screwd

Strany 9

5-17 5.2.3 Fixing the faceplate Before fixing the faceplate, first read the following sections (up to page 5-20) and then return here. The preceding

Strany 10

5-18 5.5 How do I connect the other contacts in the ABUS wireless alarm system? 5.5.1 Connecting a wired sounder The ABUS wireless alarm system is fit

Strany 11

5-19 NOTE: 1. You can connect external equipment to clamp N.O instead of to clamp N.C. If you connect to clamp NC (normally closed), the circuit

Strany 12

ABUS WIRELESS ALARM SYSTEM These installation instructions are published by ABUS Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affin

Strany 13

5-20 5.6 How are the standby batteries used? The ABUS alarm system is equipped with 6 standby batteries that maintain operation during a power failure

Strany 14

5-21 5.7 What are the effects of the different jumper settings? The PC board of the ABUS wireless alarm system is fitted with internal jumpers. Confi

Strany 15

6-22 Chapter 6 Programming the ABUS wireless alarm system There are several ways of programming your ABUS wireless alarm system: • At the alarm syste

Strany 16

7-23 Chapter 7 Settings in installer menu This chapter describes the options and features of the installer menu of your ABUS wireless alarm system. T

Strany 17

7-24 7.2 11 System Under System, you make settings that affect the entire system. This is an overview of the menu options according to their sequence

Strany 18

7-25 Timers: Quick-Key Parameter Default Range 11 11 22 Exit/Entry delay 2 Exit and entry delay times of Group 2. Make these settings as for Group

Strany 19

7-26 System Control: Quick-Key Parameter Default Range 11 22 0101 Quick arm YES YES/NO YES: No user PIN is necessary for activating the system o

Strany 20 - CAUTION:

7-27 System Control: Quick-Key Parameter Default Range 11 22 1111 Buzzer  Bell NO YES/NO YES: If the system is activated internally and an

Strany 21

7-28 System Control: Quick-Key Parameter Default Range 11 22 2020 Pager NO YES/NO Enables alphanumeric output of system events on a pager. The n

Strany 22

7-29 System Control: Quick-Key Parameter Default Range 11 22 2929 Global Follower NO YES/NO YES: Specifies that all zones (that are programme

Strany 23 - 00 11 33 33

Contents Chapter 1 Usage in accordance with regulations ...

Strany 24

7-30 7.2.3 11 33 Receiver Under Receiver, you can make settings that control the radio receiver of your ABUS wireless alarm system. To access the Rec

Strany 25

7-31 Receiver: Quick-Key Parameter Default Range 11 33 44 Delete detectors Deletes all trained wireless detectors simultaneously. To delete the wi

Strany 26

7-32 7.2.5 11 55 Labels Under System Label, you name the system and areas 1, 2 and 3, and change default names. To enter a new name: Use the buttons

Strany 27

7-33 System Label: Quick-Key Menu option Default Selection 11 55 22 to 11 55 44 Partitions 1 – 3 Partitions 1–3 Any 12 characters Changes the dis

Strany 28

7-34 Tamper Sound: Quick-Key Parameter Default Range 11 66 22 Speaker Volume Adjusts the volume of the integrated sounder in the event of an alarm

Strany 29

7-35 7.2.9 11 99 Version The Version menu shows the current version of the alarm system. To access the Version menu: 1. Select the main menu System

Strany 30

7-36 7.3 22 Zones The Zones menu enables you to train wireless detectors for the system, program zone types, and define zone dependencies. This is an

Strany 31

7-37 22 11 ZZZZ 44 Supervision Select whether a zone is to be monitored for regular reporting by the detectors to the alarm system. Set the monitor

Strany 32

7-38 Parameter Quick-Key Parameter Default Range Zone termination A wired zone is monitored using a weak electric current. The electric current is d

Strany 33 - for partition 1

7-39 Parameter Quick-Key Parameter Default Range 22 22 33 Zone Partition Partitions 1–3 Under Partition, you assign zones to different areas. Th

Strany 34

7.5.2 22 Partition ...

Strany 35

7-40 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 0101 Exit/Entry 1 Armed/internal A zone programmed as Exit/Entry 1 must not b

Strany 36

7-41 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 0909 I+Entry follow (Interior+Entry Follower) Armed The I+Entry follow zone

Strany 37

7-42 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 1818 Exit Termination A zone with the Exit Termination zone type behaves li

Strany 38

7-43 Zone sound Quick-Key Parameters Default Range 22 22 55 ZZZZ + 11 Silent No audible alarm is generated. An alarm is transmitted by telephone

Strany 39

7-44 7.3.3 22 33 Zone Testing Under Testing, you can check the correct functioning of zones. To access the Testing menu: 1. Select the Zones menu as

Strany 40

7-45 7.3.4 22 44 Editing Under Editing, you can copy and delete programmed zones. To access the Editing menu: 1. Select the Zones menu as described

Strany 41

7-46 Editing Quick-Key Parameter 22 44 44 Delete a partition Deletes a selected partition. All zones assigned to this partition are also deleted. 1.

Strany 42

7-47 7. After programming the type of interdependency, press to um define the time interval between 1 and 9 minutes. The menu for programming the

Strany 43

7-48 7.4 33 Outputs Under Outputs, you program the relay and transistor outputs of the system. You link different system events to the activation of t

Strany 44

7-49 Define Quick-Key Parameter 33 11 UOUO11 0404 Trouble Follow The switch output is activated if a system fault is detected. It is deactivated as s

Strany 45

1-5 Chapter 1 Usage in accordance with regulations The ABUS wireless alarm system is used for protecting flats and homes and small to medium business

Strany 46

7-50 Define Quick-Key Parameter 33 11 UOUO22 0808 Duress Follow The switch output is activated if a forced alarm is triggered on the operating panel i

Strany 47

7-51 33 11 UOUO33 Follow Zone This menu option lists events for a zone. 33 11 UOUO33 11 Zone Follow The switch output is activated if the selected

Strany 48

7-52 Output mode An output mode has to be set for every output. This table gives an overview of the different output modes: Outputs Quick-Key Paramet

Strany 49

7-53 Activation/Deactivation If the switch output follows more than one area or zone, you can use different patterns for activating and deactivating

Strany 50

7-54 7.5 44 Codes Under Codes, you can define user and installer Codes, define authorities, and assign areas. The ABUS wireless alarm system also has

Strany 51

7-55 Authority Levels The Authority Levels menu option contains settings for the following authorities: Grand Master: There is only one Grand Maste

Strany 52

7-56 7.5.2 44 22 Partition Default: Partition 1 Under Partition, you assign to user PINs partitions for which you have authority. The Grand Master is

Strany 53

7-57 7.5.4 44 44 Installer Default: 0133 With the installer PIN, you have access to the installer menu and thus the authority to change all system pa

Strany 54

7-58 7.5.6 44 66 Code Length Default: four digits Under Code Length, you can change the number of digits used (4 or 6) for the Grand Master, the Manag

Strany 55

7-59 7.6 55 Dialer The Dialer menu enables you to transmit alarms as voice text by telephone. In this menu, you also make the settings necessary for

Strany 56

2-6 Chapter 2 Safety information For damage caused by non-compliance with these installation instructions, no guarantee claims are possible. No liabil

Strany 57

7-60 Access Code and ID Quick-Key Parameter Default 55 55 11 Access code 5678 Defines an access code for remote programming. The four-digit access

Strany 58

7-61 Controls Quick-Key Menu option Default 55 66 0202 FM Enable NO YES: Enables FM (= Follow Me) transmission. (See also Follow Me, page 7-64.)

Strany 59

7-62 Controls Quick-Key Menu option Default 55 66 1010 Answering Machine Override YES YES: Answering machine override is activated. • The upload/

Strany 60

7-63 Dialer: Parameter Quick-Key Parameter Default Range 55 77 44 22 Wait 9 seconds Press 22 followed by . 55 77 55 Redial wait 30 seconds 30 or

Strany 61

7-64 Dialer: Parameter Quick-Key Parameter Default Range 55 77 99 22 UD Test Hr:00 Min:00 00-24 hours 00-59 minutes Under this option, enter the fo

Strany 62 - • Press to exit the menu

7-65 7.6.5 55 99 Follow Me (FM) Under this menu option, you define the forwarding of an alarm as a voice text to a telephone or a security service. I

Strany 63

7-66 Follow-Me Quick-Key Parameter Default 55 99 22 Events restore Defines whether a new call is made if the event (from section 5.9.1) is reset.

Strany 64 - on BTO (bell time out)

7-67 7.7 77 Key-fobs Under key-fobs, you learn how to train up to eight 4-button key-fobs with rolling code to work with the ABUS wireless alarm syst

Strany 65

7-68 7.7.2 77 22 Parameters Under Parameters, you program the function and the keys of the remote control. The four buttons of the remote control can

Strany 66

7-69 If you select the switch output function and confirm it with , you see the following on the display: Select a utility output with or and co

Strany 67

3-7 Chapter 3 Introduction to the ABUS wireless alarm system Congratulations – you made the right choice! The ABUS wireless alarm system offers you p

Strany 68

7-70 7.8 88 Keypads Under Keypads, you can assign two operating panels to the ABUS wireless alarm system. The following is an overview of the menu opt

Strany 69

7-71 7.8.2 88 22 Communication Test Under Communication Test you test the radio communication between your wireless operating panel and the system. T

Strany 70

7-72 7.9 99 Siren Under Siren, you can assign 3 sounders to the ABUS wireless alarm system. You can choose between internal wireless sounders and exte

Strany 71

7-73 7. Confirm the Write menu option with and your alarm system waits for a signal from your sounder. Send a message from the sounder. 8. Inser

Strany 72

7-74 7.9.3 99 33 Communication test Under communication test you test the radio communication between your sounder and the system. To access the commu

Strany 73

7-75 7.9.5 99 55 Tamper Mute Under Tamper Mute, you can deactivate the tamper function of the sounder for the current programming process. This enabl

Strany 74

7-76 7.10 00 Exit Programming Under Exit Programming, all your settings in the installer menu are saved and you exit the installer menu. Important: T

Strany 75

8-77 Chapter 8 Programming within the user programming menu This chapter explains an important menu option in the user menu. This menu option is for

Strany 76

8-78 8.1.1 77 11 Message structure Under Message structure, you define the sequence in which the voice messages are transmitted. To define a message

Strany 77

8-79 Voice message: message name Quick-Key Parameter Default Range Recording stops automatically after 10 seconds. If you want to stop recordi

Strany 78

3-8 3.2 What is the ABUS wireless alarm system? The ABUS wireless alarm system is an alarm system specially designed and developed for house owners an

Strany 79

8-80 Message Labels Quick-Key Parameter Default Range 77 22 33 Partition Message Press 33. You see the following on the display: Press or t

Strany 80

8-81 Message Labels Quick-Key Parameter Default Range 77 22 55 Macro Message Press 55. You see the following on the display: Press or to

Strany 81

8-82 Voice message: Message test Quick-Key Parameter Default Range 77 33 11 Send message Under this menu option, you can transmit a test message

Strany 82

8-83 8.1.4 77 44 Local Announcement Messages Under this menu option, you adapt local voice announcements to your requirements. To activate/deactivat

Strany 83

8-84 8.2 Walk test Under the Walk test menu option, you can test your installation. When the system is in walk-test mode, you can trigger detectors wi

Strany 84

9-85 Chapter 9 Accessories for your ABUS wireless alarm system The following is a list of accessories for your ABUS wireless alarm system. Wireless

Strany 85

10-86 Chapter 10 Brief guide This chapter explains the installation steps shown on the DVD for the ABUS wireless alarm package including a smoke detec

Strany 86 - Chapter 10 Brief guide

10-87 10.2 Training the detectors for the ABUS wireless alarm system 10.2.1 Installer menu of the ABUS wireless alarm system • First press the star

Strany 87

10-88 10.2.3 Programming zones You do not have to program the zones for the detectors in your package. They are already programmed for you as follows:

Strany 88

10-89 10.4 Exiting the installer menu All wireless components in the package are now trained. Your ABUS wireless alarm system is almost ready for ope

Strany 89

3-9 The following graphic gives you an overview of further function properties of your ABUS wireless alarm system:

Strany 90

10-90 • Confirm the menu option phone number 1 with the Enter button. • On the system keypad, enter the number with local area code and if necess

Strany 91

11-91 Chapter 11 Example of an installation plan The following table provides an overview of the information your installation plan should contain:

Strany 92

11-92 Partition Zone number Detector Zone type Name 1 2 3 4 5 6 7 8 9 10 11 12 13 1

Strany 93

11-93 Appendix A: Event Log Messages This appendix provides descriptions of all the Event Log messages(ver 1.2xx) EVENT MESSAGE DESCRIPTION Activat

Strany 94

11-94 EVENT MESSAGE DESCRIPTION Forced P=X Partition X is force armed Found Z=XXX Wireless zone found, zone No. XXX Func=XX C=YY Quick key function

Strany 95

11-95 EVENT MESSAGE DESCRIPTION Spec. main KP Special alarm from the WisDom emergency keys Soak fail Z=XXX Zone XXX has failed in the Soak test