7-29
System Control:
Quick-Key Parameter Default Range
11
22
2626
IMQ Install NO
YES/NO
ES: If a zone is open when the system is activated, the system is activated but an alarm
is generated when the exit delay time expires.
NO: Open zones are automatically omitted following expiry of the exit delay time.
11
22
2727
Grand Master
Authority/Partition
ES
YES/NO
ES: Areas and authority levels can be changed by the installer in the installer menu and
in the user menu using a Grand Master pin.
NO: Areas and authority levels can only be changed by the installer in the installer menu.
11
22
2828
Disarm Stop FM
ES
YES/NO
ES: Forwarding of calls is stopped when the system is deactivated.
NO: Forwarding of calls is continued even if the system is deactivated.
Notes
If a block lock is used, you can deactivate the system only if the block lock is opened.
However, if the system is deactivated by telephone, the calls are continued.
11
22
2929
Global Follower NO
YES/NO
ES: Specifies that all zones (that are programmed to follow an exit/entry delay time)
follow the exit/entry delay time of ALL activated areas – i.e., that the system is not
activated until after expiry of the longest exit delay time.
NO: Specifies that all zones (that are programmed to follow an exit/entry delay time) will
only follow an exit/entry delay time of the area for which they are defined.
11
22
3030
Area NO
YES/NO
Changes the function of the system as follows:
ES: A zone assigned to more than one area is not monitored until all areas are
activated, and it continues to be monitored until all areas are deactivated.
NO: A zone assigned to more than one area is not monitored until all areas are
activated, and it continues to be monitored until one area is deactivated.