37
18.9.6. Internal and external activation
In this example, partition 1 is switched from internal activation (external perimeter protection) to external activation (completely activated).
The system should have external perimeter protection from 18:00 onwards and a complete activation from 20:00 onwards.
The change from internal to external activation cannot be made without an interruption of <
1 minute
(e.g. 19:59 Æ 20:00).
If detectors with the Part Set (P) property are set up for partition 1, you can Menu item in week planner: Use Auto Set to Part Set for
partition 1.
Create data record 2 as detailed in the Auto Set and Auto Unset sections.
Set Y, activation time 18:00, Part Set Y and Partitions 1 - - - .
Set Y, deactivation time 19:59 and Partitions 1 - - - .
Create data record 3 as detailed in the Auto Set and Auto Unset sections.
Set Y, activation time 20:00, Part Set N and partitions 1 - - - .
Unset time 07:20 on the following day (Tuesday) with data record 1.
Please make sure to use the data record 1 on the next day for deactivation.
There is a danger of losing track of the programming.
( Installer mode - Detector)
Detector in partition 1 with the property: P
(Week Planner)
Part Set: Y for partition 1
Set 18:00 Unset 19:59
Monday Tuesda
y
Time P1 P2 P3 P4 P1 P2
P
00:00 00:00
01:00
02:00
03:00 S
04:00
05:00
06:00
07:00 07:20 07:20
08:00
09:00
10:00
11:00
12:00
13:00
14:00
15:00
16:00
17:00
18:00 18:00
19:00 P
20:00 19:59
21:00 20:00
22:00 S
23:00
00:00
Data record 1
Data record 2
Monday
Data record 3
Activation
Tuesday
Data record 1
Deactivation
Activation Monday, 20:00 Select the next day (Tuesday) Deactivation Tuesday, 07:20