68
UK
15
Set Comp1
This output is active for 10 seconds
after the system has been activated.
16
Unset Comp1
This output is active for 10 seconds
after the system has been deactivated
or after an alarm has been deactivated.
17
System Alarm
This output is activated when the alarm
centre has detected an alarm.
In a partitioned system
18
Bell Partition A
This output is active when an alarm has
been detected in partition A.
19
Bell Partition B
This output is active when an alarm has
been detected in partition B.
20
Bell Partition C
This output is active when an alarm has
been detected in partition C.
21
Bell Partition D
This output is active when an alarm has
been detected in partition D.
22
Strobe Set Partition A
This output is active for 10 seconds
after partition A has been activated.
23
Strobe Set Partition B
This output is active for 10 seconds
after partition B has been activated.
24
Strobe Set Partition C
This output is active for 10 seconds
after partition C has been activated.
25
Strobe Set Partition D
This output is active for 10 seconds
after partition D has been activated.
26
Set 1
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
27
Set 2
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
28
Set 3
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
29
Set 4
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
The output is also activated if a fire or
panic alarm is triggered.
30
Unset 1
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).
31
Unset 2
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).
32
Unset 3
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).